3 recorded inspectionsPlumbing installed; proper backflow devices — Inspector Note: Observed 3 compartment sink (wash compartment) pipe leaking from the base of the sink. 511-6-1.06(2)(r) - System Maintained in Good Repair (P, C) (r) System Maintained in Good Repair. A plumbing system shall be repaired according to law; P and maintained in good repair.
Physical facilities installed, maintained, and clean — Inspector Note: Observed broken and cracks on kitchen wall base tiles next to dry storage room. 511-6-1.07(5)(a),(b) - Good Repair, physical facilities maintained; Cleaning, Frequency & Restrictions, cleaned often enough to keep them clean (C) (5) Maintenance and Operation. (a) Good Repair. All physical facilities shall be maintained in good repair. PIC placed work order for repairs.
Adequate ventilation and lighting; designated areas used — Inspector Note: Observed hood lights are out and walk-in freezer light not bright enough to see. 511-6-1.07(3)(f) - Lighting Intensity, adequate in food prep, storage & service areas (C) (f) Lighting Intensity. The light intensity shall be: 1. At least 10 foot candles (108 lux) at a distance of 30 inches (75 cm) above the floor, in walk-in refrigeration units and dry food storage areas and in other areas and rooms during periods of cleaning; 2. At least 20 foot candles (215 lux): (i) At a surface where food is provided for consumer self-service such as buffets and salad bars or where fresh produce or packaged foods are sold or offered for consumption; (ii) Inside equipment such as reach-in and under-counter refrigerators; (iii) At a distance of 30 inches (75 cm) above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms; and 3. At least 50 foot candles (540 lux) at a surface where a food service employee is working with food or working with utensils or equipment such as knives, slicers, grinders, or saws where employee safety is a factor. PIC indicated a work order has been placed.
Insects, rodents, and animals not present — Inspector Note: Observed gap underneath the kitchen back door. 511-6-1.07(2)(m) - Outer Openings Protected (C) (m) Outer Openings, Protected. 1. Except as specified in paragraphs 2 through 5 of this subsection, outer openings of a food service establishment shall be protected against the entry of insects and rodents by: (i) Filling or closing holes and other gaps along floors, walls, and ceilings; (ii) Closed, tight-fitting windows; and (iii) Solid, self-closing, tight-fitting doors. PIC advised to close the gap or use a weather strip
Utensils, equipment and linens: properly stored, dried, handled — Inspector Note: observed failure to air dry containers/pans before stacking (wetnesting). Advised PIC to make sure that the containers/pans are air-dried before stacking. Stack one horizontal, the next vertical, the next horizontal, and so on.