Official Inspection History
2 recorded inspectionsWarewashing facilities: installed, maintained, used; test strips — Inspector Note: Observed dish machine chlorine sanitizer solution 0 ppm in ware wash area in kitchen. PIC instructed to discontinue utilizing dish machine and manually wash/rinse/sanitize all utensils until serviced by EcoLab. Must correct within 10 days. 511-6-1.05(2)(cc) - Warewashing, Automatic Dispensing of Detergents and Sanitizers (Pf) (cc) Warewashing Machines, Automatic Dispensing of Detergents and Sanitizers. A warewashing machine that is installed after September 12, 2007 shall be designed and equipped to: automatically dispense detergents and sanitizers Pf and incorporate a visual means to verify that detergents and sanitizers are delivered or a visual or audible alarm to signal if the detergents and sanitizers are not delivered to the respective washing and sanitizing cycles. Pf
Insects, rodents, and animals not present — Inspector Note: Observed vermin trap holding several dead roaches stored on top of dish machine, underneath dish machine and three compartment sink in kitchen. CA: PIC removed traps holding dead roaches during inspection, contacted EcoLab pest control services to schedule monthly treatment services during inspection. 511-6-1.07(5)(l) - Removing Dead or Trapped Birds, Insects, Rodents, and Other Pest (C) (l) Removing Dead or Trapped Birds, Insects, Rodents, and Other Pests. Dead or trapped birds, insects, rodents, and other pests shall be removed from control devices and the premises at a frequency that prevents their accumulation, decomposition, or the attraction of pests.
Nonfood-contact surfaces clean — Inspector Note: Observed soiled reach-in cooler gaskets. CA: Clean reach in cooler gaskets in kitchen 511-6-1.05(7)(d) - Nonfood-Contact Surfaces (C) (d) Nonfood-Contact Surfaces. Nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues.
Plumbing installed; proper backflow devices — Inspector Note: Observed water leaking from the 3 compartment sink faucet. CA: shall repair within 10 days. 511-6-1.06(2)(r) - System Maintained in Good Repair (P, C) (r) System Maintained in Good Repair. A plumbing system shall be repaired according to law; P and maintained in good repair.