K KaldiScores
Henry County
School Onsite Kitchen Henry County Permit: 075-02-fsvc-001595

Hickory Flat Elementary School

841 Brannon Rd, McDonough, GA 30253

93 A
Most Recent Score
Excellent
Routine • 2026-03-25
Public Records Freshness: Data current as of September 16, 2026.
Verify live on official Henry Health portal ↗
For Restaurant Operators

Do you manage or own Hickory Flat Elementary School?

Claim this listing for free ($0) to post a dated, verified public response detailing repairs, vendor receipts, or corrective actions taken.

Official Inspection History

2 recorded inspections
A (93) Routine Most Recent
Inspection Date: 2026-03-25 • Violations Cited: 3
Ref: insp_ga_075-02-fsvc-001595_2026-03-25_46930
Cited Observations & Standards
Item 16B Good Retail Practice

Plumbing installed; proper backflow devices — Inspector Note: Observed water heater located underneath sanitizer sink of 3-compartment sink leaking on the floor. Manager was advised to have heater repaired or removed.511-6-1.06(2)(r) - System Maintained in Good Repair (P, C) (r) System Maintained in Good Repair. A plumbing system shall be repaired according to law; P and maintained in good repair.

Item 17D Good Retail Practice

Adequate ventilation and lighting; designated areas used — Inspector Note: Observed ventilation hood not working properly. 511-6-1.07(3)(g) - Mechanical Ventilation, sufficient capacity to prevent buildup of heat, steam, smoke, fumes & odors (C) (g) Mechanical Ventilation. If necessary to keep rooms free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes, mechanical ventilation of sufficient capacity shall be provided.

Item 4-2B Critical / Risk Factor

Food-contact surfaces: cleaned & sanitized — Inspector Note: Observed quaternary ammonium sanitizer in sink below proper minimum concentration. Employee remade sanitizer solution to proper concentration. 511-6-1.05(6)(n) - Manual and Mechanical Warewashing Equipment, Chemical Sanitization-Temperature, pH, Concentration, Hardness (P,Pf) (n) Manual and Mechanical Warewashing Equipment, Chemical Sanitization - Temperature, pH, Concentration, and Hardness. A chemical sanitizer used in a sanitizing solution for a manual or mechanical operation at contact times specified under subsection (8)(b)3 of this Rule shall meet the requirements specified in DPH Rule 511-6-1-.07(6)(g), shall be used in accordance with the Environmental Protection Agency (EPA)-registered label use instructions P, and shall be used as follows: 1. A chlorine solution shall have a minimum temperature based on the concentration and pH of the solution as listed in the following chart; P Concentration Range Minimum Temperature MG/L PH 10 or less oF (oC) PH 8 or less oF (oC) 25-49 120 (49) 120 (49) 50-99 100 (38) 75 (24) 100 55 (13) 55 (13) 2. An iodine solution shall have a minimum temperature of 68°F (20°C)P minimum concentration between 12.5 ppm and 25 ppm, P and pH of 5.0 or less or a pH no higher than the level for which the manufacturer specifies for the solution to be effective; P 3. A quaternary ammonium compound solution shall have a minimum temperature of 75ºF (24ºC), P have a concentration as specified in DPH Rule 511-6-1-.07(6)(g) and as indicated by the manufacturer’s use directions included in the labeling, P and be used only in water with 500 ppm hardness or less or in water having a hardness no greater than specified by the EPA-registered label use instructions; P 4. If another solution of a chemical specified under paragraphs 1 through 3 of this subsection is used, the permit holder shall demonstrate to the Health Authority that the solution achieves sanitization and the use of the solution shall be approved; P 5. If a chemical sanitizer other than chlorine, iodine, or a quaternary ammonium compound is used, it shall be applied in accordance with the EPA-registered label use instructions ;P and 6. If a chemical sanitizer is generated by a device located on-site at the food service establishment, it shall be used as specified in 1-5 of this subsection and shall be produced by a device that: (i) complies with law as specified in sections 2(q)(1) and 12 of the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA), P (ii) complies with 40 CFR 152.500 Requirement for Devices and 40 CFR 156.10 Labeling Requirements, P (iii) displays the EPA device manufacturing facility registration number on the device, Pf and (iv) is operated and maintained in accordance with manufacturer’s instructions. Pf. 7. On-site chemical sanitizer generating equipment with active ingredients, such as copper, must be registered as pesticides. The active ingredient may be part of the equipment or separately added.

A (96) Routine
Inspection Date: 2025-09-05 • Violations Cited: 2
Ref: insp_ga_075-02-fsvc-001595_2025-09-05_46929
Cited Observations & Standards
Item 15C Good Retail Practice

Nonfood-contact surfaces clean — Inspector Note: Observed rust accumulation on shelving units in walk-in cooler and shelving storing single-use trays. 511-6-1.05(7)(a)2,3 - Equipment, Food/Nonfood-Contact Surfaces, and Utensils, food-contact surfaces of cooking equipment & nonfood-contact surfaces free of accumulations (C) 2. The food-contact surfaces of cooking equipment and pans shall be kept free of encrusted grease deposits and other soil accumulations. 3. Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.

Item 18 Good Retail Practice

Insects, rodents, and animals not present — Inspector Note: Observed accumulation of dead insects in dish room and under dish machine. Spider webs were observed throughout the facility. PIC was advised to clean under equipment and clear dead insects.